For the purposes of clarification and consistency as well as further improvement, the following additional changes shall apply:

1) Page 15, Figure 2.2
In the Table against FR116 C, delete the dimension 'A' limit (as it is no longer applicable)


2) Page 15, Figure 2.3 & Page 22, Para 4.5.4.3
The wire weight should be specified.
i.e. Amend the new caption to the new figure to read as follows:
"Minimum length and maximum wire weight: see Para. 4.5.4.3."

In the table in Para 4.5.4.3:
Amend sentence to read: "Termination types define length and weight of insulated wire or ... etc"

Add a new column to the table: "Max Weight" with values as follows:
FR112, FR113: See 3901/013
FR114, FR115: See 3901/013
FR116 to FR116D2: See Figure 2.2


3) The term 'Shell' shall be replaced by "Insert' consistently throughout the specification.
i.e.: also in Paras 4.5.4, 4.5.4.1 (Page 22)


4) Page 23, Table 2 & Pages 26, 27, Table 6
Delete "Mated Shell Conductivity" from these tables as well as note 1 in Table 2 (as this test is not applicable, as specified in Para 4.2.x, and hence there is no need to include it in the test tables)