The original DCR attachment is deleted and replaced; see "DCR894 Attachment
- 4001028 New APPENDIX A.docx"

Note: This new Appendix A includes changes applicable to the External Visual
Inspection criteria to be applied to Variant 02 during testing by
Isabellenhuette (i.e. changes to inspection during Chart F3 in Para 8.1
Overload and Para 8.6 External Visual Inspection, and Chart F4 in Paras 8.8,
8.9, 8.11 & 8.12, Rapid Change of Temperature, Vibration, Robustness of
Terminations & Resistance to Soldering Heat respectively).

The changes (inspection criteria) specified in the new Appendix A have been
agreed by ESA, DLR, TESAT, TAS and the Manufacturer Isabellenhuette.

Note: one additional minor amendment was made in Appendix A in the 'Marking
of Traceability Information' section: example was updated to H41 (was W41)
........................







Changes