- Test Requirements
Zero Power Resistance shall be measured using suitable test equipment
having an accuracy of ±0.05% or better.
All measurements shall be made in a controlled uniform medium capable of
maintaining an accuracy of ±0.01°C. The time response of the equipment used
to measure the temperature shall be compatible with that of the thermistor
under test.

- Mounting Method
Suitable test leads/connections shall be used to connect the thermistor
under test to the test equipment. For thermistor beads, flat clips shall be
used.