The version of the spec to be published includes the following changes to 3006 Draft 3C which were discussed and agreed between CNES/ESA/Exxelia and were also reviewed and accepted during the PSWG review of this DCR

1. Para. 7.1.2 Distribution within the Qualification Test Lot: the wording regarding specific sampling for the Qualification Test Lot has been deleted. The detailed Qualification Test Lot sampling requirements are now defined in Note 1 to Chart F4.

2. Para. 8.9 Climatic Sequence: Dry Heat Test Ba has been withdrawn, it has therefore been replaced by Test Bb; Cold Test Aa has been withdrawn, it has therefore been replaced by Test Ab.

3. Radiographic Inspection, performed in accordance with ESCC Basic Specification No. 20900, has been added. Radiographic Inspection shall be performed on a sample basis during Subgroup 2A of Chart F4 (Qualification, Periodic Testing and Lot Validation Testing).