Appendix on TD testing Note: The total number of documents affected by this DCR is 92 (i.e. all HCMOS Detail Specifications except 9205/016 and 9207/008: see attached spreadsheet for list)
A new deviation shall be added to Appendix A in all 92 Detail Specifications:
ITEMS AFFECTED: Deviations from the Generic Specification: Deviation from Product Control - Chart F2
DESCRIPTION OF DEVIATIONS: Total Dose Radiation Testing: The following deviation from the procedures for qualification and procurement lot acceptance in ESCC Basic Specification No. 22900 shall apply: The radiation exposure and test sequence requirements including radiation levels, time intervals for measurement, and the flow chart for qualification and lot acceptance testing, may be replaced by the requirements of ST radiation test procedure 0043082.
|