Add the following to 'Deviations from Screening Tests - Chart F3' (part of Appendix 'A' - Agreed Deviations for Peregrine Semiconductor Europe):
"Radiographic Inspection shall be performed in accordance with ESCC Basic Specification No. 20900. The Manufacturer may perform the inspection at any point during Screening Tests subsequent to Serialisation."
The text shall be added to the Description of Deviations column as a new item below "Room Temperature Electrical Measurements may be performed after Seal Test (Fine and Gross Leak)."
It follows that Paragraphs 1.2 (Applicable Documents) and 2.1 (Deviations from Generic Specification) are not affected.
The above change is also necessary for, and shall therefore be applied to, two other Detail Specs for components manufactured by PSE - ESCC 9202/078 Issue 1; ESCC 9202/079 Issue 1.
|
|
|