This change is best implemented in the Manufacturer's appendix as a deviation to the generic spec 3401 per para 4.2.2 of the detail spec.
..........
Appendix A
AGREED DEVIATION FOR C&K COMPONENTS (F)
Items Affected
Para. 4.2.2, Deviations from Final Production Tests (Chart II)
Description of Deviations
Para. 9.4, Contact Capability: 100% Contact Capability Test may be omitted provided that a
100% visual inspection of the contact and a 10% Contact Capability test are performed in accordance with the C&K PID requirements. The results of the Contact Capability test shall be considered for PDA.
|
|
|