DCR is approved with the following additions:
New item: Emitter-Base Voltage maximum rating is applicable over the entire operating temperature range, table amended accordingly.
New item: Collector Current maximum rating corrected from “10us pulse” to “continuous”
Item 12: Change DCRs wording from “…differs between the two package types” to “…differs between the two different breakdown voltage options”.