Accepted with modifications: Written by Thomas Schulze Modifications
The DCR changes are replaced by the following as were proposed by Isabellenhuette (see DCR attachment dlr_proposal_dcr_1188_(4001_027)_r1.docx for details):
Para. 1.4.2
For Variants 01, 02, 03, change Min Rn value in table to be 0.010ohm (was 0.0050)
Add new Variants 04, 05, 06 for Rn <10mohm as per DCR attachment
Amend Note 2 and add new note 3 as per DCR attachment
Para. 1.5
Add new Variants 04, 05, 06 to Rated Dissipation in table as per DCR attachment
Para. 1.6
Add new Variants 04, 05, 06 to dimension table as per DCR attachment
Para. 2.1.1.1
Add new Variants 04, 05, 06 to deviation on infrared Measurment as per DCR attachment.
Para. 2.5.2
Add new Table for Variants 04, 05, 06 as per DCR attachment. Original table applies to "For Variants 01, 02, 03 Resistance ≥10mOhm"
Para. 2.7.2
Add new Variants 04, 05, 06 to Biased Burn-in table as per DCR attachment.
|