Document change request DCR774
















Based on the review performed by the PSWG adhoc WG on ceramic capacitor generic specification as implemented into ESCC3001 issue 2, the following modifications shall apply to this DCR:

a) All changes, including these modifications, have been implemented in the new DCR attachment 3001/027 draft 2C (which shall replace the original DCR attachment).

b) Ref. original DCR item 1) General:
The following additional editorial and technical amendments resulting from the changes made to the test requirements of the Generic Specification No. 3001, shall apply:
• Para. 4.2.4 is deleted.
• Table 6: Climatic Test Sequence requirements are deleted.
• Table 6: Damp Heat Steady State is deleted and replaced by Steady State Humidity (85/85) test requirements.
• Table 6: Add notes applicable to Operating Life, to explain when the 1000h & 2000h measurements apply.

c) Ref. original DCR item 9) Table 2 & 6: units Gohm.nF are used for Insulation Resistance (instead of sec)

d) Ref. original DCR item 10): The required ambient temperatures are added to the Temperature Characteristic conditions

Note that the Manufacturer’s name has changed since this DCR was originally raised (now Exxelia Technologies). Appendix A amended accordingly.







Changes






Optimized for:

© 2010 European Space Agency. All rights reserved.

Display Sitemap