Changes and corrections to the original DCR wording, based on the review comments provided by Manufacturer, are as follows:
The proposed, attached specification shall be 4001/029 issue 2 Draft B.
For item 5: add reference to Para 4.2.5 and add the following bullet:
" - Delete the deviations from Paras 4.2.4(c) & 4.2.5(b) (as there is no deviation applicable)."
Delete item 12 (as the operating life is not 'continuous' but is the standard ON/OFF method per ESCC4001 para 8.13).
|
|
|