Based on discussions with Manufacturer C&K, the contents of this DCR should be amended to be as follows:

Proposed Wording Of Change:

Page 36 Para 4.5.4.5
Amend table header for last column to be:
Number of Coaxial or Power Contact Cavities (Note 1)


Add new note 1 to be as follows(& renumber other notes accordingly):
............
1. For connectors with contact arrangements that include coaxial or power contact cavities, the coaxial or power contacts shall be ordered separately in accordance with ESCC Detail Specification Nos. 3401/004 and 3401/040 respectively.

Coaxial and power contacts must be from the same Manufacturer as the connector in which they are mounted and this shall be verified prior to assembly.
...................


--------------------------------------------------------------------------------

Justification:
To be consistent with the current process applied in practise by the Manufacturers.

--------------------------------------------------------------------------------






Changes

Optimized for:

© 2010 European Space Agency. All rights reserved.