Maximum Ratings table: Characteristic Collector-Base Voltage amended from 150V to 110V (consistent with the sole supporting Manufacturer's data sheet).
11. Changed wording as follows: Figure 2 re-named "Physical Dimensions and Terminal Identification"; Figure 2(a) deleted (all related Variants are obsolete); Figures 2(b) and 2(c) amended (standardisation of the TO-257 package).
14. Changed wording as follows: Case requirements corrected to reflect the TO-257 metal flange mount packages.
|
|
|