The following additional changes are included in this DCR:
A - Spec Title & Para 1.1
Change spec title & para 1.1 to read "based on Series MSCI 10K, 12K, 20K and H01"
B - Table 1(a) Range of Components
For the new RANGE OF COMPONENTS table for H01 Series the "Type Number" in column 1 shall reflect the ESCC standard value code as defined in para 4.5.3.1 plus shall include the 15% tolerance code letter "L" for all values.
i.e. The correct codes for the 14 new items in the new Table shall be as follows:
L38L (was: K38)
L67L (was: K67)
1L0L (was: 1K0)
1L5L (was: 1K5)
2L0L (was: 2K0)
2L7L (was: 2K7)
3L4L (was: 3K4)
4L6L (was: 4K6)
5L6L (was: 5K6)
7L1L (was: 7K1)
100L (was: 10K)
120L (was: 12K)
270L (was: 27K)
101L (was: M10)
The header row of the Table should be equivalent as for the current 20K range (including column numbers & parameter symbols).
The units and values in column 8 (Rated DC Current) should all be converted to mA to be consistent with the other tables
e.g.
1st line should read 1500mA
Last line should read 100mA

3 - Para 4.5.3.2 Tolerances
Add row for new tolerance 15% with code letter "L"