The following clarifies the changes required to implement this DCR:
For 3401/065 and 3401/039:
Add new note 1 to Contact Resistance (Rated Current) in Table 2 as follows:
"Note 1: Contact Resistance at Rated Current is guaranteed but not tested during Final Production Tests (Chart II)"
For 3401/017:
Add new note 1 to Contact Resistance (both Low Level Current & Rated Current) in Table 2 as follows:
"Note 1: Contact Resistance is guaranteed but not tested during Final Production Tests (Chart II)"
|
|
|