All other references in the specification to the operating temperature of +125C shall also be changed to be +110C i.e. in Para 2.3.2 High and Low Temperature Electrical Measurements.
The Rise Time and Fall Time limits in the tables Paras 2.3.1, 2.3.2, 2.5, 2.9.2 (for fNom: 16MHz to 100MHz) are changed from 5ns to 7ns.

Note: for these tests in the table in Para 2.3.2, the test at 125C is removed and the test at 105C is changed to be at 110C.

Note: several additional minor editorial changes have been implemented in this issue including the addition of ESCC specification hyperlinks & internal cross-references.








Changes

Optimized for:

© 2010 European Space Agency. All rights reserved.