Modifications
In addition to the correction of the drawing for Figure 2(b) for 13-04 per the original DCR1193, the following additional changes were made:
1) All drawings in Figure 2(b) were replaced by better quality drawings as provided by Manufacturer Souriau.
2) Missing drawings for special contact arrangements 09-01, 15-97, 23-21, 25-03, 25-07 (that are already listed in Para 4.5.4.2) are added to Figure 2(b).
3) Specific Souriau special contact arrangements that are not in conformity to MIL-STD-1560, are identified as such with * in figure 2(b) (ref note 1 to Figure 2(b))
i.e.: 09-01, 11-01, 13-26, 17-75, 25-03, 25-07.
In addition several editorial changes were made including:
· References to MIL-C-38999 is updated to be MIL-DTL-38999.
· replace obsolete MIL-STD-1344 by the MIL recommended replacement: EIA-364-54 in Para 2 & 4.2.2(a).
· Title for MIL-STD-1560 is updated in Para 2.
· Add hyperlinks for all ESCC & MIL spec references.
· Add internal paragraph cross-references.
|