Replace the original DCR1100 contents by the following as discussed and agreed with the DCR originator: Radiall:

Documents affected: ESCC 3402/002, ESCC 3402/003, ESCC 3402/005, ESCC 3402/006, ESCC 3402/009, ESCC 3402/010, ESCC 3402/022, ESCC 3402/023, ESCC 3402/027, ESCC 3402/028.

Para: 4.2.2 Deviations from Final Production Tests (Chart II)
Add the following new deviation:
(a) Para. 9.4, Coupling Proof Torque: shall not be performed on connectors with a female contact (only during Chart II).


Add the following to the Justification for this DCR:
Performing the Coupling Proof Torque on connectors with female contacts does risk damage occurring due to the severity of the test. Hence, for connectors with female contacts, this test shall only be performed during Qualification Tests - Chart IV & Lot Acceptance Tests - Chart V.