In order for full and proper implementation of this DCR the following other documents shall be included:
ESCC 3001
ESCC 3009/xxx Detail Specifications (i.e. / 003, 004, 005, 006, 008, 009, 010, 011, 022, 023, 034, 037, 038, 039, 040, 041, 042, 043)
ESCC 3001/xxx Detail Specifications (i.e. / 027, 028, 030, 033, 034, 037, 038)


........................
The changes proposed for ESCC 3009 Para 8.10 & Chart F4 shall also be implemented into ESCC3001 Para 8.13 & Chart F4 with the same details.

........................
For each 3009/xxx & 3001/xxx Detail Specification, replace with the following amendments:

A) Implement Insulation Resistance into the 'High and Low Temperature Electrical Measurements' table with the following Details:
: test temperature: Tamb = +125 +/-2degC

: Test method and Conditions: per ESCC 3009 or 3001 and add new Note 1 as below

: Limits: as per each applicable previous ESCC Detail Spec revision that included Insulation Resistance at high temperature (in Table 3)(but with units: Gohm or Gohm.nF as applicable)

: Add new Note 1 (Other notes in the table to be renumbered & reallocated accordingly):
1. Guaranteed but not tested during Chart F3 Screening Tests; only tested in Temperature Characterisation during Chart F4 Qualification and Periodic Testing.


B) In the 'Intermediate and End-Point Electrical Measurements' table:
amend title of test 'Capacitance-Temperature Characteristics' to be 'Temperature Characterisation'

Add Insulation Resistance, RI, as the first test in 'Temperature Characterisation' with existing Note # as below in the limits column.

Note # (# number as applicable):
#. As specified in High and Low Temperatures Electrical Measurements.

Additional Modifications

The following additional editorial changes, agreed by PSWG81, shall apply:



For ESCC3001:

The paragraphs applicable to the amended Para 8.13 should be corrected to be:

in new (a): Para. 8.6.1.3

in new (b): Para. 8.6.1.5



The associated test box in Chart F4 should be renamed: Temperature Characterisation





For ESCC3009:

The associated test box in Chart F4 (& test title in Note 7) should be renamed: Temperature Characterisation







Changes

Optimized for: