The following amendments have to be added:

1) Table 1(a)
For clarification & presentation purposes, I propose to amend the column header for FR112 etc to read:
"FR11x & FR12x (1)(3)"

Plus add new note 3:
"3. Includes termination type codes: FR112 to FR116, FR112A to FR115A, FR112B to FR115B, and FR123, FR123A FR123B."


2) Figure 2.5
All other characteristics need to be specified for the 2 new wires options.
i.e.:
For ESCC 3901/012 AWG 26 & 28:
Nominal Cross-section: 0.15 & 0.08
Maximum Weight: 2.11 & 1.35
Colour: red / white (see comment below)
Minimum Length: See Para. 4.5.3.3

Comment on Colour: since my initial comment, C&K have confirmed that red wire will be used for AWG26 3901/012 options & white wire for AWG28 3901/012 options.

Note: for the nominal cross-section of ESCC3901/012 Variant 01 wire (AWG28), the value should be corrected to be 0.089 (was 0.1)


3) Para 2. The correct title for ESCC 3901/012 should be used
i.e.:
ESCC Detail Specification No. 3901/012, EXTRUDED, CROSS-LINKED FLUOROPOLYMER INSULATED WIRES AND CABLES ON SILVER-PLATED COPPER CONDUCTOR, LOW FREQUENCY, 600V, -100 TO +200°C






Changes

Optimized for: