Modifications: The change to contact voltage drop (= contact resistance) proposed for 3602/019 (1A, 2PDT, 1/6 CRYSTAL CAN
Latching Relay) shall also apply to related spec 3601/012 (1A, 2PDT, 1/6 CRYSTAL CAN Non-Latching Relay). i.e.: Para 2.4.1, Room Temperature Electrical Measurements, Contact Voltage Drop: change limit to be "0.1 xITest" (was "0.05 xITest")
In addition, in Para 2.4.2 High and Low Temperature Electrical Measurements, make the same change to Contact Voltage Drop limits.
In addition, in Para 2.6, Intermediate and End-Point Electrical Measurements, for tests Low Level Life, Resitive Life (Final Measurements), Intermediate Current (Final Measurements), Overload (Final Measurements) make the following related change to Contact Voltage Drop Limits: change limit to be "0.2 xITest" (was "0.1 xITest")
|